HEBEIOUTAI ENVIRONMENTAL PROTECTION EQUIPMENT CO.,LTD.

SSS

Common Faults, Causes and Measures of Bag Filter
Fault phenomenon cause Exclusion measures
Filter bag wear Rubbing with the box Repair damaged bag or replace
Dust abrasion (thinning of filter bag under the filter) Check the cause and deal with
Damage caused by adjacent filter bags Repair damaged bag or replace
Filter bag burned Inflow of fire Elimination of fire
Dust fever Eliminating dust and cooling
Filter bag clogging Long use time of filter bag replace
Process gas contains moisture Check the cause and deal with
Filter bag wet Repair, plugging
Excessive wind speed Reduce wind speed
Poor cleaning Strengthen dust removal and check cleaning mechanism
Abnormal increase in resistance Spray pipe plugging Clearing and clearing
Dust removal mechanism malfunctions Check and troubleshoot
Dust, humidity, clogging, or poor cleaning Control dust humidity, clean and clear
Ash setting time incorrect Adjust the timer time
Rapping mechanism malfunctions (mechanical rapping and cleaning) Check and adjust
Reduced cylinder air pressure Check and increase the pressure of compressed air
Poor solenoid valve for cylinder Check and adjust
A lot of ash in the hopper Clear dust
Filter bag clogging Check the reason, clear the jam
Filter bag is wet due to water leakage Patching loopholes
Dust off the dust collector Dust and humidity Check the cause and troubleshoot
Dust removal mechanism malfunctions Check, adjust and troubleshoot
Dust cleaning solenoid valve fails Inspection and replacement
Defective timer set value is incorrect or has failed Check and adjust the time setting value
Insufficient spray Check the reason and increase the injection pressure
Poor cylinder operation Poor solenoid valve operation Check the cause and fix
Leakage Inspection, plugging
Piston Rod Corrosion Rust removal or replacement
Poor travel Adjustment schedule
Broken pressure pipe repair
Pressure pipe joint cracks, falls off Repair and tighten
Insufficient pressure in compressed air Increase the pressure of pressure
Compressor does not arrive Check and clear the pipeline
Poor solenoid valve operation Circuit failure Check the circuit and troubleshoot
Due to long-term static friction increase Inspection
Valve wear replace
Spring break Replace spring
Foreign matter in the valve Remove foreign matter Sealed
Dust in the ash bucket cannot be discharged Dust in the lower part of the hopper Remove dust plug
Spiral cutter failure Check and troubleshoot
Rotary valve malfunction Inspection, repair
Dust consolidation Clean up consolidation dust
Exclude flow channel blockage Clean the flow cell and remove foreign matter
Dust is wet and hard to fall Cleaning dust, moisture treatment